CEMB SPA – Mandello del Lario
1.3.5. Analog output.
Each vibration channel sends an output signal 4 to 20 mA proportional to the RMS
value of the vibration speed measured.
1.3.6. Environmental conditions.
The instruments operate correctly within a temperature range from –10°C to +
50°C.
1.3.7. Power supply.
Instrument power supply is 220 Vac – 50 Hz
1.3.8. Composition of the instruments.
Each instrument is mounted in a 19” rack enclosure able to process at least 16
measuring channels. The following are installed in the unit:
- one power supply complete with main switch
- a number of signal processing boards which depend on the number of fans to be
monitored.